Welcome to Hebei Bendin Industrial Technology Co., Ltd.
+8619567910927

Data Center Non Conductive Fiberglass Cable Tray IEC 61537 for Cable Separation

Basic Properties
Place of Origin: China
Brand Name: Bendin
Certification: IEC 61537
Model Number: Non Conductive Fibreglass Cable Tray For Data Center
Trading Properties
Minimum Order Quantity: 100m
Price: 5usd
Payment Terms: L/C,T/T
Supply Ability: 10000000m/month
Product Summary
Non Conductive Fibreglass Cable Tray For Data Center 1. The Core Functional Advantages of Non-Conductive Fibreglass Cable Trays in Data Centers In the high-density, mission-critical environment of a modern data center, the choice of cable containment material directly affects operational safety, ...

Product Details

Highlight:

Non Conductive Fiberglass Cable Tray

,

Data Center Fibreglass Cable Tray

,

IEC 61537 Fibreglass Cable Trough

Product Name::: Non Conductive Fibreglass Cable Tray For Data Center
Keywords::: Non Conductive Fibreglass Cable Tray
Material::: Flame-Retardant FRP / Glass Fibre Reinforced Plastic
Certification:: IEC 61537
Application:: Data Center
Type::: Cable Tray
Product Description

Non Conductive Fibreglass Cable Tray For Data Center


1. The Core Functional Advantages of Non-Conductive Fibreglass Cable Trays in Data Centers
In the high-density, mission-critical environment of a modern data center, the choice of cable containment material directly affects operational safety, signal integrity, and long-term reliability. Glass Reinforced Plastic (GRP) cable trays, also known as FRP (Fiberglass Reinforced Plastic) trays, are manufactured from pultruded glass fibre composites that deliver a unique combination of properties unmatched by traditional steel systems. The most fundamental of these is electrical non-conductivity: with insulation resistance exceeding 10¹²Ω, fibreglass trays eliminate any risk of short circuits or electrical leakage, allowing maintenance teams to work safely in live environments without de-energising circuits. This non-conductive nature also removes the need for the complex earthing and bonding systems that metallic trays require, reducing both installation complexity and the number of ongoing inspection points. Equally important is the material's non-magnetic character. Metallic cable containment can contribute to electromagnetic interference (EMI) in high-density networking zones, degrading signal quality and system stability. GRP is non-metallic and non-magnetic, eliminating any risk of interference with sensitive networking equipment, fibre optic cabling, and switching hardware. Furthermore, fibreglass trays are highly corrosion-resistant, UV-stable, and weigh up to 70% less than equivalent steel trays, which simplifies handling and reduces structural loading on floors and ceilings—an important consideration in multi-floor data halls where every kilogram matters. With a design life exceeding 50 years and minimal maintenance requirements, GRP cable trays can reduce total ownership costs by 30 to 40 percent compared to traditional metallic systems.

 

2. Application Scenarios and Their Corresponding Certification Requirements
Different zones within a data center impose different regulatory and certification demands on non-conductive cable trays, and specifying the correct product requires an understanding of these distinctions. In underfloor cable routing areas—common in raised-floor data centres—trays are typically installed at a height not exceeding 150 mm, and metallic channels must be bonded to the room's equipotential grounding terminal at both ends; because fibreglass trays are non-conductive, a separate earthing main line must be arranged independently alongside the tray run. For certification in these environments, compliance with IEC 61537 (Cable Management—Cable Tray Systems and Cable Ladder Systems) is the primary international requirement, with additional fire-safety testing to IEC 60695-2-11 for non-metallic components, where non-current-carrying parts must withstand a 650 °C glow-wire test. In ceiling and overhead installations, fire performance becomes the dominant certification criterion. GRP trays must demonstrate self-extinguishing properties to UL 94 V-0 and comply with low-smoke zero-halogen (LS0H) requirements to avoid toxic fume emission during a fire event, a critical concern in enclosed data halls where evacuation may be difficult. In power distribution rooms and UPS zones, products must additionally comply with IEC 62262 for mechanical impact resistance (IK ratings) and IEC 60529 for ingress protection, ensuring that accidental contact with live conductors is prevented even under physical stress. For projects in the Middle East and Southeast Asia, local certification such as SASO (Saudi Arabia) or SABER compliance may be required in addition to CE marking, while Australian projects reference AS/NZS 61537:2016 alongside the AS/NZS 3000 Wiring Rules.

 

3. Specification Types and Their Suitability for Data Center Environments
BENDIN Non-conductive fibreglass cable trays are available in three principal structural configurations, each with distinct performance characteristics suited to different data center applications. Ladder-type trays consist of two longitudinal side rails connected by rungs, typically spaced at 6, 9, or 12 inches on centre. This open design provides excellent ventilation and heat dissipation—a decisive advantage in high-density server environments where cable bundles can otherwise trap heat—and allows convenient cable binding and future re-routing. Solid trough-type trays feature a fully enclosed bottom that shields cables from dust and provides an additional barrier against electromagnetic interference, making them suitable for precision workshops and areas with strict cleanliness requirements. Channel-type trays offer a semi-open compromise, balancing protection with thermal management, and are widely used in factory power distribution and tunnel engineering. In terms of load classification, NEMA FG 1 designates fibreglass tray systems into three working load classes: Class A at 50 lbs per linear foot, Class B at 75 lbs per linear foot, and Class C at 100 lbs per linear foot, with a published safety factor of 1.5. Standard usable inside widths range from 6 to 36 inches, and loading depths are commonly 2, 3, or 5 inches per NEMA FG 1 tolerances. For data center use, ladder-type trays in NEMA Class B or C are most frequently specified for primary cable runs, while solid trough trays are reserved for fibre optic backbone routes where additional mechanical protection and EMI shielding are required.

4. Installation Considerations: Support Spacing, Thermal Expansion, and Earthing
Installing fibreglass cable trays in a data center requires attention to several factors that differ significantly from steel tray practice, and failure to account for them can lead to sagging, joint cracking, and cable damage within two to three years. The most common error is applying steel support spacing to fibreglass trays. The elastic modulus of GRP is approximately 15–30 GPa, roughly one-tenth that of steel at 200 GPa, meaning that an identically sized fibreglass tray will deflect considerably more under the same load. As a practical guideline, a standard 300 mm wide GRP ladder tray carrying 75 kg/m should be supported at intervals of 1.8 to 2.4 metres, compared with 3.0 to 3.6 metres for an equivalent steel tray. For horizontal runs in data centers, support spacing should not exceed 1.5 metres, and for vertical installation, no more than 2 metres, to avoid sagging under dense cable loads. Thermal expansion is another critical consideration. Over a 30-metre run with a 60 °C temperature variation, a GRP tray will expand approximately 32–45 mm, compared with only about 20 mm for steel. Expansion joints with sliding splice plates must therefore be installed at intervals of 9 to 15 metres, and expansion joints are mandatory whenever the laying length exceeds 30 metres. Regarding earthing, because fibreglass trays are non-conductive and cannot serve as an Equipment Grounding Conductor, an independent copper or aluminium earthing conductor must be routed alongside or within the tray system and bonded to the building's grounding network. Finally, cut edges of pultruded fibreglass sections should be sealed with a resin edge sealer to prevent moisture ingress, which can cause delamination during freeze-thaw cycles. Protective covers are also recommended for areas exposed to sustained direct UV radiation to slow surface aging.

 

Certification Requirements for Non-Conductive Fibreglass Cable Trays

Region / Country Primary Standard(s) Additional Requirements Certification Mark
International IEC 61537 IEC 60695-2-11 (glow-wire), IEC 60529 (IP), IEC 62262 (IK) Third-party test reports
European Union EN 61537 / IEC 61537 RoHS, LVD directives; UL 94 V-0 flammability CE marking
North America (USA) NEMA FG 1, UL 568, ANSI/NFPA 70 (NEC Article 392) ASTM E-84 Class 1 flame rating; ASTM D-635 self-extinguishing UL listing / NEMA compliance
North America (Canada) CSA C22.2 CSA load classifications per NEMA FG 1 methodology CSA certification
United Kingdom BS EN 61537 BS 476 Part 6/7 (fire propagation); LS0H UKCA / CE
Germany DIN 5510-2 IEC 60695-2-12/UL94; NF F 16-101 (fire behaviour) DIN certification
France NF F 16-101 / NF P 92-501 Fire classification M1, F0; UL 94 V-0 NF certification
Australia / New Zealand AS/NZS 61537:2016 AS/NZS 3000 Wiring Rules; AS/NZS 3013 classification RCM compliance
India IS/IEC 61537 IS 6746 (vinyl ester resin specs) BIS licence
Saudi Arabia / GCC SASO / SABER CE + local conformity; ASTM E84 Class 1 SASO / SABER
Russia / EAEU GOST / EAC IEC 61537 compliance; fire safety certification EAC mark

Common Specifications of Non-Conductive Fibreglass Cable Trays

Specification Parameter Standard Range / Options Notes
Tray Type Ladder, Solid Trough, Channel Ladder for ventilation; trough for EMI/dust protection
Usable Inside Width 6", 9", 12", 18", 24", 30", 36" Custom widths up to 1000 mm available
Side Rail Height 2", 3", 5" (loading depth per NEMA FG 1) Overall height 6" for deep-load configurations
Rung Spacing 6", 9", 12", 18" on centre 9" standard on fittings; 12" most common for data center
Standard Length 120" (10 ft), 240" (20 ft) Custom lengths available
Load Class (NEMA FG 1) Class A: 50 lbs/lin.ft; Class B: 75 lbs/lin.ft; Class C: 100 lbs/lin.ft Safety factor 1.5; reduce load rating above 75 °F
Material Resin System Polyester or Vinyl Ester Vinylester for enhanced chemical resistance
Insulation Resistance > 10¹² Ω Non-conductive; no earthing required for tray itself
Flammability Rating UL 94 V-0; ASTM E-84 Class 1 Self-extinguishing; halogen-free, low smoke
Operating Temperature −50 °C to +120 °C Load capacity decreases at elevated temperatures
Support Spacing (Horizontal) ≤ 1.5 m (data center recommendation); 1.8–2.4 m (general) Based on 300 mm width, 75 kg/m load
Support Spacing (Vertical) ≤ 2.0 m Manufacturer load tables should be consulted
Expansion Joint Interval Every 9–15 m; mandatory when run > 30 m Accommodates thermal expansion of 32–45 mm per 30 m at ΔT 60 °C
Corrosion Resistance No degradation after 240 h immersion in 10% HCl or NaOH Suitable for humid, coastal, and chemically exposed environments

Data Center Non Conductive Fiberglass Cable Tray IEC 61537 for Cable Separation

Data Center Non Conductive Fiberglass Cable Tray IEC 61537 for Cable Separation

Data Center Non Conductive Fiberglass Cable Tray IEC 61537 for Cable Separation

Related Products

Send An Inquiry