Non Conductive Fibreglass Cable Tray For Data Center
1. The Core Functional Advantages of Non-Conductive Fibreglass Cable Trays in Data Centers
In the high-density, mission-critical environment of a modern data center, the choice of cable containment material directly affects operational safety, signal integrity, and long-term reliability. Glass Reinforced Plastic (GRP) cable trays, also known as FRP (Fiberglass Reinforced Plastic) trays, are manufactured from pultruded glass fibre composites that deliver a unique combination of properties unmatched by traditional steel systems. The most fundamental of these is electrical non-conductivity: with insulation resistance exceeding 10¹²Ω, fibreglass trays eliminate any risk of short circuits or electrical leakage, allowing maintenance teams to work safely in live environments without de-energising circuits. This non-conductive nature also removes the need for the complex earthing and bonding systems that metallic trays require, reducing both installation complexity and the number of ongoing inspection points. Equally important is the material's non-magnetic character. Metallic cable containment can contribute to electromagnetic interference (EMI) in high-density networking zones, degrading signal quality and system stability. GRP is non-metallic and non-magnetic, eliminating any risk of interference with sensitive networking equipment, fibre optic cabling, and switching hardware. Furthermore, fibreglass trays are highly corrosion-resistant, UV-stable, and weigh up to 70% less than equivalent steel trays, which simplifies handling and reduces structural loading on floors and ceilings—an important consideration in multi-floor data halls where every kilogram matters. With a design life exceeding 50 years and minimal maintenance requirements, GRP cable trays can reduce total ownership costs by 30 to 40 percent compared to traditional metallic systems.
2. Application Scenarios and Their Corresponding Certification Requirements
Different zones within a data center impose different regulatory and certification demands on non-conductive cable trays, and specifying the correct product requires an understanding of these distinctions. In underfloor cable routing areas—common in raised-floor data centres—trays are typically installed at a height not exceeding 150 mm, and metallic channels must be bonded to the room's equipotential grounding terminal at both ends; because fibreglass trays are non-conductive, a separate earthing main line must be arranged independently alongside the tray run. For certification in these environments, compliance with IEC 61537 (Cable Management—Cable Tray Systems and Cable Ladder Systems) is the primary international requirement, with additional fire-safety testing to IEC 60695-2-11 for non-metallic components, where non-current-carrying parts must withstand a 650 °C glow-wire test. In ceiling and overhead installations, fire performance becomes the dominant certification criterion. GRP trays must demonstrate self-extinguishing properties to UL 94 V-0 and comply with low-smoke zero-halogen (LS0H) requirements to avoid toxic fume emission during a fire event, a critical concern in enclosed data halls where evacuation may be difficult. In power distribution rooms and UPS zones, products must additionally comply with IEC 62262 for mechanical impact resistance (IK ratings) and IEC 60529 for ingress protection, ensuring that accidental contact with live conductors is prevented even under physical stress. For projects in the Middle East and Southeast Asia, local certification such as SASO (Saudi Arabia) or SABER compliance may be required in addition to CE marking, while Australian projects reference AS/NZS 61537:2016 alongside the AS/NZS 3000 Wiring Rules.
3. Specification Types and Their Suitability for Data Center Environments
BENDIN Non-conductive fibreglass cable trays are available in three principal structural configurations, each with distinct performance characteristics suited to different data center applications. Ladder-type trays consist of two longitudinal side rails connected by rungs, typically spaced at 6, 9, or 12 inches on centre. This open design provides excellent ventilation and heat dissipation—a decisive advantage in high-density server environments where cable bundles can otherwise trap heat—and allows convenient cable binding and future re-routing. Solid trough-type trays feature a fully enclosed bottom that shields cables from dust and provides an additional barrier against electromagnetic interference, making them suitable for precision workshops and areas with strict cleanliness requirements. Channel-type trays offer a semi-open compromise, balancing protection with thermal management, and are widely used in factory power distribution and tunnel engineering. In terms of load classification, NEMA FG 1 designates fibreglass tray systems into three working load classes: Class A at 50 lbs per linear foot, Class B at 75 lbs per linear foot, and Class C at 100 lbs per linear foot, with a published safety factor of 1.5. Standard usable inside widths range from 6 to 36 inches, and loading depths are commonly 2, 3, or 5 inches per NEMA FG 1 tolerances. For data center use, ladder-type trays in NEMA Class B or C are most frequently specified for primary cable runs, while solid trough trays are reserved for fibre optic backbone routes where additional mechanical protection and EMI shielding are required.
4. Installation Considerations: Support Spacing, Thermal Expansion, and Earthing
Installing fibreglass cable trays in a data center requires attention to several factors that differ significantly from steel tray practice, and failure to account for them can lead to sagging, joint cracking, and cable damage within two to three years. The most common error is applying steel support spacing to fibreglass trays. The elastic modulus of GRP is approximately 15–30 GPa, roughly one-tenth that of steel at 200 GPa, meaning that an identically sized fibreglass tray will deflect considerably more under the same load. As a practical guideline, a standard 300 mm wide GRP ladder tray carrying 75 kg/m should be supported at intervals of 1.8 to 2.4 metres, compared with 3.0 to 3.6 metres for an equivalent steel tray. For horizontal runs in data centers, support spacing should not exceed 1.5 metres, and for vertical installation, no more than 2 metres, to avoid sagging under dense cable loads. Thermal expansion is another critical consideration. Over a 30-metre run with a 60 °C temperature variation, a GRP tray will expand approximately 32–45 mm, compared with only about 20 mm for steel. Expansion joints with sliding splice plates must therefore be installed at intervals of 9 to 15 metres, and expansion joints are mandatory whenever the laying length exceeds 30 metres. Regarding earthing, because fibreglass trays are non-conductive and cannot serve as an Equipment Grounding Conductor, an independent copper or aluminium earthing conductor must be routed alongside or within the tray system and bonded to the building's grounding network. Finally, cut edges of pultruded fibreglass sections should be sealed with a resin edge sealer to prevent moisture ingress, which can cause delamination during freeze-thaw cycles. Protective covers are also recommended for areas exposed to sustained direct UV radiation to slow surface aging.
Certification Requirements for Non-Conductive Fibreglass Cable Trays
| Region / Country |
Primary Standard(s) |
Additional Requirements |
Certification Mark |
| International |
IEC 61537 |
IEC 60695-2-11 (glow-wire), IEC 60529 (IP), IEC 62262 (IK) |
Third-party test reports |
| European Union |
EN 61537 / IEC 61537 |
RoHS, LVD directives; UL 94 V-0 flammability |
CE marking |
| North America (USA) |
NEMA FG 1, UL 568, ANSI/NFPA 70 (NEC Article 392) |
ASTM E-84 Class 1 flame rating; ASTM D-635 self-extinguishing |
UL listing / NEMA compliance |
| North America (Canada) |
CSA C22.2 |
CSA load classifications per NEMA FG 1 methodology |
CSA certification |
| United Kingdom |
BS EN 61537 |
BS 476 Part 6/7 (fire propagation); LS0H |
UKCA / CE |
| Germany |
DIN 5510-2 |
IEC 60695-2-12/UL94; NF F 16-101 (fire behaviour) |
DIN certification |
| France |
NF F 16-101 / NF P 92-501 |
Fire classification M1, F0; UL 94 V-0 |
NF certification |
| Australia / New Zealand |
AS/NZS 61537:2016 |
AS/NZS 3000 Wiring Rules; AS/NZS 3013 classification |
RCM compliance |
| India |
IS/IEC 61537 |
IS 6746 (vinyl ester resin specs) |
BIS licence |
| Saudi Arabia / GCC |
SASO / SABER |
CE + local conformity; ASTM E84 Class 1 |
SASO / SABER |
| Russia / EAEU |
GOST / EAC |
IEC 61537 compliance; fire safety certification |
EAC mark |
Common Specifications of Non-Conductive Fibreglass Cable Trays
| Specification Parameter |
Standard Range / Options |
Notes |
| Tray Type |
Ladder, Solid Trough, Channel |
Ladder for ventilation; trough for EMI/dust protection |
| Usable Inside Width |
6", 9", 12", 18", 24", 30", 36" |
Custom widths up to 1000 mm available |
| Side Rail Height |
2", 3", 5" (loading depth per NEMA FG 1) |
Overall height 6" for deep-load configurations |
| Rung Spacing |
6", 9", 12", 18" on centre |
9" standard on fittings; 12" most common for data center |
| Standard Length |
120" (10 ft), 240" (20 ft) |
Custom lengths available |
| Load Class (NEMA FG 1) |
Class A: 50 lbs/lin.ft; Class B: 75 lbs/lin.ft; Class C: 100 lbs/lin.ft |
Safety factor 1.5; reduce load rating above 75 °F |
| Material Resin System |
Polyester or Vinyl Ester |
Vinylester for enhanced chemical resistance |
| Insulation Resistance |
> 10¹² Ω |
Non-conductive; no earthing required for tray itself |
| Flammability Rating |
UL 94 V-0; ASTM E-84 Class 1 |
Self-extinguishing; halogen-free, low smoke |
| Operating Temperature |
−50 °C to +120 °C |
Load capacity decreases at elevated temperatures |
| Support Spacing (Horizontal) |
≤ 1.5 m (data center recommendation); 1.8–2.4 m (general) |
Based on 300 mm width, 75 kg/m load |
| Support Spacing (Vertical) |
≤ 2.0 m |
Manufacturer load tables should be consulted |
| Expansion Joint Interval |
Every 9–15 m; mandatory when run > 30 m |
Accommodates thermal expansion of 32–45 mm per 30 m at ΔT 60 °C |
| Corrosion Resistance |
No degradation after 240 h immersion in 10% HCl or NaOH |
Suitable for humid, coastal, and chemically exposed environments |