Welcome to Hebei Bendin Industrial Technology Co., Ltd.
+8619567910927

Insulation Grade FRP Cable Ladder Pultruded 50mm-1200mm Width UV Stabilized

Basic Properties
Brand Name: Bendin
Certification: ISO, CE
Model Number: cable tray ladder
Trading Properties
Minimum Order Quantity: 50m
Price: 1.5
Standard Packaging: pallet
Delivery Time: 10-20 work days
Payment Terms: L/C,T/T,Western Union
Supply Ability: 100000m
Product Summary
Pultruded FRP cable ladder delivers inherent dielectric separation and wet-proof performance for electrolytic plants and battery rooms. ISO 9001 certified, tested to ASTM D257/IEC 60093, with custom widths 50-1200mm and HDG or stainless options. MOQ 50m.

Product Details

Highlight:

Electrical Insulation Cable Ladder

,

Pultruded FRP Cable Ladder

,

Insulated Ladder Tray

Product Name:: FRP Cable Ladder Electrical Insulation
Keywords:: Electrical Insulation, FRP Cable Ladder
Name:: Ladder Cable Tray
Height:: 50-200mm
Length:: 1-3m
Width:: 50-1200mm
Key Selling Point:: Dielectric Separation, Wet Proof
Material:: Pultruded FRP
Size Range:: Width 50-1200 Mm, Height 50-200 Mm
Rung Spacing:: 225/300/450 Mm
Surface Treatment:: Pultruded, UV Stabilized
Application:: Electrolytic And Electroplating Plants
Product Description
FRP Cable Ladder Electrical Insulation

FRP Cable Ladder Electrical Insulation is supplied where the cable support itself must provide dielectric separation: process plants with live electrical equipment, electrolytic cells, battery rooms and test areas where a metallic tray would compromise the insulation coordination of the installation.

The ladder is produced in pultruded FRP, and also in hot dip galvanized or stainless steel where the project needs mechanical strength with insulating isolation only at the brackets. Widths run from 50 mm to 1200 mm, rail heights 50 mm to 200 mm, rung pitch 225 mm, 300 mm or 450 mm, in 1 m to 3 m modules for congested routes.

In the FRP version the insulation is a material property, not a coating: resistivity is measured to ASTM D257 and IEC 60093 on the finished profile, and the value holds under wet contamination because the resin matrix does not absorb water the way a filled thermoplastic can. There is no tracking path along the surface and no galvanic couple at the fasteners.

The steel version uses the same geometry with insulating standoff brackets and joint plates, which is the practical choice for long spans where the mechanical demand exceeds the composite section. Both versions share the fitting family, so a route can transition between them at a defined boundary.

BENDIN manufactures both versions at up to 100000 m per week across composite and steel lines, with 180 staff and thirty years of cable support engineering. Insulation resistance, rung strength and dimensional accuracy are inspected per batch, and project specific test certificates can be issued.

Minimum order 50 m, 10 to 20 working day delivery, prices on request, pallet packing, terms L/C, T/T or Western Union. Give us the voltage class, the fault level and the environment and we will confirm the material, the isolation arrangement and the support spacing.

Certification and Standard Reference
Standard / Specification Scope of Application BENDIN Status
ASTM D257 / IEC 60093 Surface and volume resistivity of the finished profile Resistivity tested per batch; report on request
IEC 61537 Load, deflection and system performance Design calculation and continuity check per order
IEC 61936-1 (reference) Insulation coordination in high voltage installations Documentation on request
ASTM E84 / EN 13501-1 Flame spread and smoke Resin system declared; fire test data on request
ISO 1461 Hot dip galvanized steel version Coating thickness measured per batch; record supplied
ISO 9001:2015 Quality management system ISO 9001 certified; certificate copy on request

BENDIN holds ISO 9001 quality certification and issues CE Declarations of Conformity. The standards above state the design and test basis of this product; third party test reports or national approvals are supplied on request and are not implied unless confirmed in the contract.

Technical Parameters
Parameter Standard Range Customization Available
Version Pultruded FRP HDG or stainless with isolation
Usable width 50 - 1200 mm to drawing
Rail height 50 - 200 mm to drawing
Rung spacing 225 / 300 / 450 mm custom
Module length 1000 / 2000 / 3000 mm cut to order
Resistivity Non conductive, tested project value
Fasteners Stainless, isolated A4 for marine
Support span 1.5 - 9 m material dependent

Dimensions, rung spacing and surface treatment are produced to project drawings. Load and deflection calculations are issued for spans above 3 m.

Typical Applications
  • Electrolytic and electroplating plants
  • Battery rooms and UPS installations
  • High voltage test areas
  • Chemical process buildings
  • Water and wastewater electrical rooms
Frequently Asked Questions

Q: Is the insulation affected by washdown?
A: No. Resistivity is a property of the resin matrix and holds under wet contamination, unlike a surface coating that can be breached.

Q: Can I mix FRP and steel on one route?
A: Yes. Both versions share the fitting family, so the route can transition at a defined boundary between wet and dry areas.

Q: What test documents are supplied?
A: Resistivity results per batch, plus load and deflection calculations for the specified span, and project specific certificates where required.

Q: What is the minimum order?
A: Minimum order 50 m, delivery 10 to 20 working days, prices on request.

Insulation Grade FRP Cable Ladder Pultruded 50mm-1200mm Width UV Stabilized

Insulation Grade FRP Cable Ladder Pultruded 50mm-1200mm Width UV Stabilized

Insulation Grade FRP Cable Ladder Pultruded 50mm-1200mm Width UV Stabilized

Insulation Grade FRP Cable Ladder Pultruded 50mm-1200mm Width UV Stabilized

Related Products

Send An Inquiry